1
This water heater complies with ANSI Z21.10.1-current
edition regarding the accidental or unintended ignition of
ammable vapors, such as those emitted by gasoline.
For Your Safety
AN ODORANT IS ADDED TO THE GAS USED
BY THIS WATER HEATER.
• Safety Instructions
• Installation
• Operation
PRINTED IN THE U.S.A 0410 PART NO. 317998-002
ALL TECHNICAL AND WARRANTY QUESTIONS: SHOULD BE DIRECTED TO THE LOCAL DEALER FROM WHOM THE WATER HEATER WAS PURCHASED.
IF YOU ARE UNSUCCESSFUL, CONTACT RESIDENTIAL TECHNICAL ASSISTANCE AT 1-800-365-0024 OR WWW.STATEWATERHEATERS.COM.
Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch;
do not use any phone in your
building.
Immediately call your gas supplier
from a neighbors phone. Follow the
gas suppliers instructions.
If you cannot reach your gas
supplier, call the fire department.
Installation and service must be
performed by a qualified installer,
service agency or the gas supplier.
WARNING: If the information in these
instructions is not followed exactly, a fire
or explosion may result causing property
damage, personal injury or death.
RESIDENTIAL GAS WATER HEATERS
Installation Instructions and Use & Care Guide
INSTALLER:
AFFIX THESE INSTRUCTIONS TO OR ADJACENT
TO THE WATER HEATER.
OWNER:
RETAIN THESE INSTRUCTIONS AND WARRANTY
FOR FUTURE REFERENCE. RETAIN THE
ORIGINAL RECEIPT AS PROOF OF PURCHASE.
WARNING: Gas leaks can not always be detected by
smell.
Gas suppliers recommend that you use a gas detector
approved by UL or CSA.
For more information, contact the your gas supplier.
If a gas leak is detected, follow the “WHAT TO DO IF YOU
SMELL GAS” instructions.
Care and Maintenance
• Troubleshooting
• Parts List
HIGH EFFICIENCY ATMOSPHERIC VENT
GAS WATER HEATER
(FLAMMABLE VAPOR IGNITION RESISTANT)
FOR SPACE HEATING AND POTABLE WATER HEATING ONLY.
NOT FOR USE IN MOBILE HOMES.
Vista de página 0
1 2 3 4 5 6 ... 39 40

Resumo do Conteúdo

Página 1 - For Your Safety

1This water heater complies with ANSI Z21.10.1-current edition regarding the accidental or unintended ignition of fl ammable vapors, such as those emit

Página 2 - TABLE OF CONTENTS

10Gas Pipe Capacity Table WARNING• Use a new CSA approved gas supply line.• Install a shut-off valve.• Do not conn

Página 3 - FIRE AND EXPLOSION HAZARD

11TABLE 3BTUH InputMinimum SquareFeet with8’ CeilingTypical Roomwith 8’ Ceiling30,000 188 9 x 2145,000 281 14 x 2060,000 375 15 x 2575,000 469 15 x 31

Página 4 - Fire or Explosion Hazard

1212” Max.Permanentopenings to the outside oradditional rooms within the buildingClosetor otherconfinedspace12” Max.FIGURE 4.All Air from Inside the B

Página 5 - TYPICAL INSTALLATION

13FIGURE 8B.Vent Pipe System This water heater uses a non-direct, single-pipe vent system to remove

Página 6 - Excessive Weight Hazard

14Align the legs of the draft hood with the slots provided. Insert the legs and secure the draft hood to the water heater’s top with the four screws p

Página 7 - FV Sensor

15Piping Installation Piping, fittings, and valves should be installed according to the installation

Página 8 - FIGURE 1B

16Hot WaterOutletIn a closed system use athermal expansion tankCold WaterInlet ValvePressure ReducingValve with BypassMain WaterSupplyCold Water Suppl

Página 9 - GAS SUPPLY

17For protection against excessive pressures and temperatures, a temperature and pressure relief valve must be installed in the opening marked “T &

Página 10 - Explosion Hazard

18A diaphragm-type expansion tank suitable for potable water will normally eliminate this weeping condition. Please read and follow the manufacturer’s

Página 11 - Carbon Monoxide Warning

19□ Ductwork is the same cross-sectional area as the openings.Vent Pipe SystemCheck for proper drafting at the water heater draft hood. Refer to the

Página 12 - Openings

2TABLE OF CONTENTSWater Heater Safety ...

Página 13 - FIGURE 7

20WARNINGExplosion HazardReplace view port if glass is missingor damaged.Failure to do so can result in death,explosion or fire.Operating Instructions

Página 14 - FIGURE 10

21MATCHRELIEFOPENINGDRAFT HOOD FIGURE 18.If the flame flutters or is blown out, combustion products are escaping from the relief opening. If this occu

Página 15 - WATER SYSTEM PIPING

22Burner FlamesInspect the burner flames through the viewport and compare them to the drawings in Figure 19. A properly operating burner should produc

Página 16

23Good venting is essential for a gas fired water heater to operate properly as well as to carry away products of combustion and water vapor. It is al

Página 17 - Drain Line

24Powered Anode OperationTo protect the glass-lined water tank from corrosion through electrolysis, this water heater is equipped with a non sacrifici

Página 18 - TYPE OF INSTALLATION

25properly. To prevent water damage, the valve must be pro- perly connected to a discharge line which terminates at an adequate drain. Standing clear

Página 19

26Replacing the Flame Sense/Hot Surface igniter Assembly1. Remove the manifold/burner assembly. See Removing the Manifold/Burner Assembly.2. Lift th

Página 20 - WARNING: TURN OFF ALL

273. Insert the manifold/burner assembly into the burner compartment making sure that the tip of the manifold tube engages in the slot of the bracket

Página 21 - Doing so can result in burns

28TROUBLESHOOTING CHARTPROBLEM POSSIBLE CAUSE(S) CORRECTIVE ACTIONNO HOT WATER1. Transformer unplugged.2. No power at outlet.3. Thermostat defec

Página 22 - Water Temperature Regulation

29PROBLEM POSSIBLE CAUSE(S) CORRECTIVE ACTIONCOMBUSTION ODORS1. Insufficient secondary air.2. Water heater flue or vent system blocked.3. H

Página 23 - Operational Conditions

3SAFE INSTALLATION, USE AND SERVICEYour safety and the safety of others is extremely important in the installation, use and servicing of this water he

Página 24 - Draining and Flushing

30 Please check guidelines below. For your safety, water heater service should be performed only by a qualied service person.Read the GENERAL SAFETY

Página 25 - Explosion Harzard

31 6. “P-SW”, “OPEN”, and “CLEAN SCREEN” Flashing The air pressure switch contacts remain open longer than 5 seconds after the combustion fan is en

Página 26 - Air Intake Chamber

32cont. 11. “FV-SENSE” and “OPEN” Flashing Flammable Vapor Sensor is open 1. Check all wiring to the ammable vapor sensor. 2. Remove the conn

Página 27 - Manifold Tab

33Please Note:The control continually monitorsinternal circuits and external sensors.Error codes noted above, and those forself-diagnostic faults can

Página 28 - Operational Checklist

34Item No.Parts Description1 Draft Hood2 Flue Baffle3 Nipple (Hot)4 Nipple (Cold)5 Anode Rod6 Cold Water Inlet Tube7 Temperature and Pressure Valve8 C

Página 29

35Listed Parts Kits and Illustrations

Página 31

37NOTES

Página 32

38NOTES

Página 33 - TROUBLESHOOTING FLOWCHART

39THIS WARRANTY IS APPLICABLE TO THE ORIGINAL OWNER ONLY in accordance with the warranty terms and conditions specifi ed below.The warrantor will furni

Página 34 - Repair Parts List

4Fire or Explosion HazardDo not store or use gasoline or other flammable vapors andliquids in the vicinity of this or any other appliance. Avoid all i

Página 35

40LIMITATION ON IMPLIED WARRANTIESImplied warranties, including any warranty of merchantability imposed on the sale of this heater under state law are

Página 36

5TYPICAL INSTALLATIONGET TO KNOW YOUR WATER HEATER - GAS MODELS A Vent Pipe B Draft hood C Anode (Not Shown) D Hot Water Outlet E Insulation F

Página 37

6INSTALLING YOUR GAS WATER HEATERImportant Information About This Water Heater This gas water heater was manufactured to voluntary safety standa

Página 38

7Location Requirements Carbon Monoxide Poisoning HazardWARNINGDo not install in a mobile home. Doing so

Página 39

8IMPORTANT: The water heater should be located in an area where leakage of the tank or connections will not result in damage to the area adjacent to t

Página 40 - CLAIM PROCEDURE

9Manual GasShut-Off ValveInstall a readily acces-sible manual shut-off valve in the gas supply line as recommended by the local utility.Check with loc

Modelos relacionados GP 6 50YPC T 100

Comentários a estes Manuais

Sem comentários